LOW-COST, INTELLIGENT DATA ACQUISITION SYSTEM FOR QCM AND OTHER RESONATOR-BASED BIO- AND CHEMICAL SENSORS

Authors

  • Sergey Y. Yurish

DOI:

https://doi.org/10.47839/ijc.7.2.504

Keywords:

Data acquisition system, sensors, method of the dependent count, frequency-to-digital converter, UFDC-2

Abstract

A low-cost, intelligent data acquisition system for quartz crystal microbalance (QCM) and other (superficial SAW and bulk acoustic wave) resonator-based chemical and biosensors described in this article. The system is based on the novel modified method of the dependent count and allows obtaining high metrological performances: programmable and constant in all frequency range relative error of measurement up to 0,0005 % (5 ppm); nonredundant, reduced conversion time of measurement and wide frequency range from 0.05 Hz to 9 MHz (144 MHz with prescaling). The developed system allows measuring variations of the resonance frequency shift for QCM sensors working in liquids and gases. The described low-cost data acquisition system is based on novel integrated circuit of universal frequency-to-digital converter. This design approach has eliminated much of the hardware: there is no need for a microcontroller and complex sensor interfacing electronics, as it is directly compatible with PC computers.

References

C. Di Nucci, A. Fort, S. Rocchi, L. Tondi, N. Uliviery, V. Vignoli, F. Di Francesco, M. B. Serrano-Santos, Study of the Dynamic Response of QCM sensors my means of a fast and accurate all-digital frequency detector. Proceedings of “IEEE Instrumentation and Measurement Technology Conference”, Anchorage, USA, 2002, (CD-ROM).

M. T. S. R. Gomes, Bulk acoustic wave sensors in chemical analysis. Smart Sensors and MEMS, S. Y. Yurish, M. T. S. R. Gomes, Ed. , Springer Verlag, 2005, pp.421-445.

R. Lucklum, R. Borngraeber, P. Hauptmann, Acoustically amplified chemical QCM-sensor with frequency and attenuation output. Proceedings of “Transducers ’99”, Sendai, Japan, 1999, pp.1250-1253.

Hatfield, A. R. Daniels, D. Snowden, K. C. Persaud, P. A. Payne. Development of a hand held electronic nose (H2EN). Proceedings of “European Conference on Solid-State Transducers” (EUROSENSORS XIII), The Hague, The Netherlands, 1999, pp. 215-218.

Inacio, J.N. Marat-Mendes, C. J. Dias. Development of a biosensor based on a piezoelectric film. Proceedings of “European Conference on Solid-State Transducers” (EUROSENSORS XVI), Prague, Czech Republic, 2002, vol.3, pp.763-764.

E. Katz. Electronic biosensors based on biomaterial-nanoparicle hybrid systems. Smart Sensors and MEMS, S. Y. Yurish, M. T. S. R. Gomes, Ed., Springer Verlag, 2005, pp.447-474.

S. R. Suri. Quartz crystal based microgravimetric immunobiosensors. Sensors & Transducers, (66) (2006), pp. 544-552.

S. Kurosawa, H. Aizawa, M. Tozuka, M. Nakamura, J.-W. Park. Immunosensors using a quartz crystal microbalance, Measuring Science and Technology, (14) (2003), pp. 1882-1887.

L. A. Kuznetsov, M. V. Milonov, D. V. Nalivkin. A method for high-precision measurements of vibration frequency of piezoelectric sensors. Sensors & Systems, February 2004 pp.2-6 (in Russian).

M. T. Hill, A. Cantoni. Precise all-digital frequency detector for high frequency signals. IEEE Transactions on Communications, (48) (2000), pp.1937-1944.

Shankar, S.A. Morris, C.G. Hutchens. A novel measurement technique for quartz microbalance systems and other resonator-based sensor systems. Proceedings of “Sensors for Industry Conference (Sicon/02)”, Houston, Texas, USA, 2002, pp.134-138.

N. V. Kirianaki, S. Y. Yurish, N. O. Shpak. Methods of dependent count for frequency measurements, Measurement, (29), 2001, pp.31-50.

N. V. Kirianaki, S. Y. Yurish, N. O. Shpak, V. P. Deynega. Data Acquisition and Signal Processing for Smart Sensors. Chichester, UK: John Wiley & Sons, 2001.

N. V. Kirianaki, S. Y. Yurish, Method of measurement for frequency and period of harmonic signal and device for its realization, UA Patent No. 81851, G01R 23/02, February 2008.

N. V. Kirianaki, B. M. Berezyuk. Method of measurement for frequency and period of harmonic signal and device for its realization, USSR Patent 788018, December 1980.

L. A. Vinogor, N. V. Kirianaki. Device for frequency and period measurement of harmonic signal, Russia Patent 1797714, February 1993.

Yurish S. Y., Intelligent Data Acquisition System for Quartz Crystal Microbalance and Other Resonator-Based Sensors. Proceedings of IEEE International Workshop on Intelligent Data Acquisition and Advanced Computing Systems: Technology and Applications, 6-8 September 2007, Dortmund, Germany, pp. 2-7.

S. Y. Yurish, N. V. Kirianaki, R. Pallas-Areny, Universal frequency-to-digital converter for quasi-digital and smart sensors: specification and applications, Sensor Review, 25 (2) (2005), pp. 92-99.

R. Stone, P.A. Payner. Measurement of the response of resistive sensors using logic oscillators and integrated frequency measurement, Sensors and Actuators A: Physical, 76 (1-3) (1999), pp.431-436.

Downloads

Published

2014-08-01

How to Cite

Yurish, S. Y. (2014). LOW-COST, INTELLIGENT DATA ACQUISITION SYSTEM FOR QCM AND OTHER RESONATOR-BASED BIO- AND CHEMICAL SENSORS. International Journal of Computing, 7(2), 9-17. https://doi.org/10.47839/ijc.7.2.504

Issue

Section

Articles